Free NFPA 660 compliance checklist

Is your woodworking shop ready for NFPA 660?

Answer ten questions about your shop as it runs today. In about three minutes you get a readiness score and a plain-language list of the gaps an inspector would likely find. "Not sure" is a fine answer: it's a gap worth checking.

10questions inspectors actually ask about
3 minto your score and gap list
Freegap report and review by our team
Höcker dust collector installed outdoors beside a woodworking plant, away from occupied areas

    Free gap report

    Get your gap report and a plan to close it

    We email your score and gap list, then review it with you and tell you what to fix first. No charge, no obligation.

    This check covers common NFPA 660 requirements for woodworking facilities. It does not replace a Dust Hazard Analysis or an engineering review. Questions? Call Bennett at 616.881.6698. Privacy policy

    Your gap report is on the way

    Check your inbox for your score and gap list. We'll follow up within one business day with what to fix first.

    Want to talk now? Call Bennett at 616.881.6698.

    Quick answer

    What does NFPA 660 require of a woodworking shop? NFPA 660 is the combustible dust standard that replaced NFPA 664 for woodworking. To meet it, a shop needs a current Dust Hazard Analysis, a dust collector located and protected for explosion risk, isolation and spark control, grounded metal ductwork, a housekeeping program, trained employees, a way to review changes, and documented inspections.

    What this NFPA 660 compliance checklist covers

    Ten things that decide if you're ready for an inspection

    What NFPA 660 is, and what happened to NFPA 664

    NFPA 660, the Standard for Combustible Dusts and Particulate Solids, took effect December 6, 2024. It folded six standards into one, including NFPA 664 (woodworking) and NFPA 652 (fundamentals). Woodworking now sits in Chapter 24. Some states and cities still enforce NFPA 664 until they adopt 660, so ask your fire marshal.

    Does NFPA 660 apply to your woodworking shop?

    If your machines make fine wood dust and your system collects it, almost certainly yes. Your fire marshal enforces it through the local fire code, and OSHA inspects under its Combustible Dust National Emphasis Program (reissued January 30, 2023), citing hazards under the General Duty Clause. See the top citations to watch out for.

    On the walk-through

    What an inspector asks to see for each item

    Inspectors ask for proof. Most items come down to paperwork, so a shop can do the right things every day and still come up short.

    #Checklist itemWhat they'll ask to see
    1Dust Hazard AnalysisA written DHA, who did it, when, and proof it was reviewed in the last five years or after your last big change
    2Collector locationWhere the collector sits, and the engineering behind any collector inside the building
    3Explosion protectionVenting, flameless venting or suppression on the collector, sized for that collector and your dust
    4IsolationA backdraft damper or isolation valve on the inlet, plus protection on the return air path if cleaned air comes back inside
    5Ignition controlSpark detection and extinguishing, and how tramp metal and hot material are kept out of the system
    6DuctworkMetal duct (no plastic pipe), connected and grounded so static can't build up, with flex hose only for short hookups at the machines
    7HousekeepingA written cleaning program, and clean beams, ledges and machine tops on the day of the visit
    8TrainingTraining records for everyone who works around wood dust
    9Management of changeHow you review a new machine, a moved duct or a new material before it goes in
    10Inspection and maintenanceLogs showing the collector, vents, dampers and detectors are inspected on a schedule

    Scoring

    How the checklist scores your shop

    Yes earns 10 points, Not sure earns 4, No earns 0. Your score is the share of possible points you earned, from 0 to 100.

    90 to 100Strong footing

    The basics are in place. Make sure the paperwork backs it up.

    60 to 89Gaps to close

    You have a foundation, but at least one gap could turn into a citation or a fire.

    Below 60High priority

    Several core protections are missing or unknown. Start with the gap list and bring in an engineer.

    Not sure earns partial credit because something may be in place that nobody wrote down. An inspector treats it like "no," so it still lands on your gap list.

    Common gaps

    Where woodworking shops usually fall short

    Most gaps aren't dramatic. They're the slow kind that build up while everyone is busy making product.

    The DHA was never done, or never opened again

    A DHA is a living document. If you've added machines since it was written, it no longer describes your shop. Read why the DHA is the foundation of safety.

    The shop grew, but the system didn't

    Add a CNC router and two branch lines to an old system and air speed drops, so dust settles inside the ducts. Check your airflow with the dust collector CFM calculator.

    Plastic pipe and long flex hose

    Both build static charge, and neither can contain a fire. It's one of the easiest problems to spot on a walk-through.

    Dust on top of everything

    Beams, lights and ledges collect dust for years. In an explosion, the first blast shakes it loose, and that cloud is what levels a building.

    No isolation on the return air

    Sending clean, heated air back into the shop saves real money. That return path needs its own protection, designed in from the start.

    Waste handling as an afterthought

    When the bin or trailer fills faster than anyone empties it, material backs up into the collector. Dust collection should never be the reason your shop stops.

    Collectors moved indoors without a second look

    Indoor collectors face tighter rules. Before you bring one inside, read the NFPA rules for interior dust collection.

    Designed in, not bolted on

    Why NFPA 660 compliance starts with your dust collection system

    Explosion protection, isolation, spark control, ductwork and inspections all live in or around the dust collection system. Most of compliance is designed in, or out, the day the system is laid out.

    We design the whole system around your shop: machines, ductwork, waste and safety, always with safety components and blast gates. If your current system isn't working, we redesign it as a whole. We won't bolt a new fan onto someone else's ductwork. More on when you need spark detection.

    What to do after the checklist

    1. Clean up today. Housekeeping is the cheapest fix on the list and lowers your risk right away.

    2. Find your DHA, or schedule one. If it's more than five years old, or you've changed the shop since, it needs an update.

    3. Write down what you already do. Not sure answers often turn into Yes once someone documents the training and inspections that already happen.

    4. Have the system looked at. Collector location, explosion protection, isolation and ductwork are design questions, not cleaning questions.

    5. Send us your gap report. Use the form above and we'll review it with you for free.

    Questions

    NFPA 660 compliance checklist FAQs

    What is NFPA 660?

    NFPA 660 is the Standard for Combustible Dusts and Particulate Solids. It took effect on December 6, 2024, and combined six earlier NFPA standards, including NFPA 664 for woodworking and NFPA 652 for the fundamentals, into one document.

    Does NFPA 660 replace NFPA 664?

    Yes. NFPA 664 is one of the six standards NFPA 660 replaced. The woodworking requirements now sit in Chapter 24, and the fundamentals chapters apply alongside them. Some jurisdictions still enforce NFPA 664 until they adopt NFPA 660, so check with your fire marshal.

    Is NFPA 660 compliance required by law?

    NFPA standards become enforceable when your state or local fire code adopts them, and your fire marshal enforces them. OSHA can also cite combustible dust hazards under the General Duty Clause, and uses NFPA standards as evidence that the hazard is recognized in the industry.

    Does OSHA inspect woodworking shops for combustible dust?

    Yes. OSHA's Combustible Dust National Emphasis Program, reissued in January 2023, lists sawmills, lumber resawing and planing, and several kinds of furniture manufacturing among its target industries. Housekeeping problems are typically cited under OSHA's housekeeping rule.

    How often does a Dust Hazard Analysis need to be updated?

    Review and update your DHA at least every five years, and sooner after any significant change to your equipment, materials, process or building, such as adding machines or moving ductwork.

    Who can perform a Dust Hazard Analysis?

    A qualified person with real knowledge of combustible dust hazards, the NFPA standards, and how your facility runs. Many shops hire an outside fire protection engineer or a combustible dust specialist.

    Is my existing dust collection system grandfathered?

    Don't count on it. The DHA requirement covers existing facilities, not just new construction, and adding, moving or replacing equipment can bring parts of your system under current requirements. Your DHA is what tells you where your system stands.

    Is wood dust really explosive?

    Yes. When fine wood dust hangs in the air, it can ignite and burn fast enough to build pressure inside an enclosure like a dust collector. How hard a dust explodes is measured by its deflagration index, or Kst.

    Does this NFPA 660 compliance checklist replace a Dust Hazard Analysis?

    No. This checklist is a quick self-check that shows where to look first. A DHA is a detailed, documented analysis of your specific facility, and it's required. Use your gap list to make that conversation faster.

    Sources: NFPA 660, Standard for Combustible Dusts and Particulate Solids; OSHA, Combustible Dust; OSHA Directive CPL 03-00-008, Combustible Dust National Emphasis Program (January 30, 2023).

    This page is general guidance for woodworking facilities, not a compliance determination. Your local fire marshal or authority having jurisdiction makes the final call.